Begin Part Validation | MMCD Service (SRVC)

Begin Part Family self validation test
ERROR: Required Parameter not found: Inner Pipe Width
ERROR: Parameter may be used more than once, index must be greater than zero: SRS (StructRimToSumpHeight[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PDom (Catalog_Domain[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PTyp (Catalog_PartType[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PSTyp (Catalog_SubType[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PrtNm (Catalog_PartName[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PrtD (Catalog_PartDesc[0])
ERROR: Parameter may be used more than once, index must be greater than zero: DVer (DataVersion[0])
ERROR: Parameter may be used more than once, index must be greater than zero: CntTy (Content_Type[0])
ERROR: Parameter may be used more than once, index must be greater than zero: HPrtF (Catalog_PartHide[0])
ERROR: Parameter may be used more than once, index must be greater than zero: SBS (StructBoundingShape[0])
ERROR: Parameter may be used more than once, index must be greater than zero: CusSF (CustomPartSizing_Flag[0])
ERROR: Parameter may be used more than once, index must be greater than zero: SVPC (StructVertPipeClearance[0])
ERROR: Parameter may be used more than once, index must be greater than zero: PrtSN (Catalog_PartSizeName[0])
ERROR: Parameter may be used more than once, index must be greater than zero: SBSD (StructDiameter[0])
OK: Part Domain parameter validated -- Structure_Domain
ERROR: Part Type parameter not validated
OK: Part Subtype parameter validated -- Undefined
OK: Part Description parameter validated -- MMCD Service (SRVC)
OK: Part Name parameter validated -- MMCD Service (SRVC)
ERROR: Part Size Name calc uses Part Name not Part Desc (corrected)
OK: Unique Part Family ID  validated -- 47DBC2D9-099F-4FC4-8871-2E4B5638D16E
OK: Data Version parameter validated, version = 2.0
OK: Sample Expanded Table row successfully created
 
Begin Calc Usage Validation
OK: Calc Parameter PrtSN uses Context=Catalog_PartSizeName
OK: Calc Parameter BdyD1 uses Context=BodyGeometry_Diameter
OK: Calc Parameter SBSH uses Context=StructHeight
OK: Calc Parameter LenB1 uses Context=Geometry_Distance3D
OK: Calc Parameter SBSD uses Context=StructDiameter
 
ERROR: Table Data Validation Failed | D:\OneDrive - APW Engineering\21-003 (MMCD DWT Update)\MMCD IDS (Autodesk Civil 3D 2022) Original\1_MMCD Civil 3D Standards\MMCD Pipes Catalog\Metric Structures\Junction Structures without Frames\MMCD Service (SRVC).xml

ERROR: Part Validation Failed | Junction Structures without Frames\MMCD Service (SRVC).xml